How do I Set Up the Roast IQ Controller?
To set up your Roast IQ Controller follow these steps:
- Connect Power & Ethernet
- Connect your probes - the controller supports B,E,J,K,N,R,S and T Type Probes
- The probes are connected via the green or black terminal plugs - you will need a small flat screwdriver to terminate the probes
- See diagram attached to connect probes
- Once connected you will need to set your probe type
- To do this - navigate to Your Roastery > Roasters > Your Roaster
- Here you will need to enter the ip address of the controller and click connect
- Once connected select edit/check hardware
- Here you can set your probe types/max temp{safety cut off] and idle temp